pH - using HI-11310 pH electrode

pH Range   basic mode: -2.00 to 16.00 pH; standard mode: -2.000 to 16.000 pH
 Resolution   basic mode: 0.01 pH; standard mode: 0.001 pH
 Accuracy (@25°C)   basic mode: ±0.01 pH; standard mode: ±0.002 pH
 Calibration   Basic Mode: Automatic, up to three points, option to select 5 standard buffers.
Standard mode: Automatic, up to five point calibration, 7 standard buffers available and two custom buffers.
   Temperature Compensation   Automatic, -5.0 to 100.0°C (using integral temperature sensor)
 Logging   Up to 1000* (in Standard Mode) records organised in:
• Manual log-on demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging in Standard Mode

mV - using HI-11310 pH electrode

  mV pH Range   ±1000 mV
 Resolution   0.1 mV
 Accuracy (@25°C)   ±0.2 mV

ORP – using HI-36180 ORP electrode

   ORP Range   ±2000.0 mV
 Resolution   0.1 mV
 Accuracy (@25°C)   ±0.2 mV (±999.9mV); ±1mV (±2000mV)
   Temperature Compensation   Automatic, using integral temperature sensor -5.0 to 100.0°C
   Logging   Up to 1000* (in Standard Mode) records organised in:
• Manual log-on demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging in Standard Mode

EC - using HI-763100 four-ring conductivity Probe

   EC Range   0.00 to 29.99 µS/cm;
30.0 to 299.9 µS/cm;
300 to 2999 µS/cm;
3.00 to 29.99 mS/cm;
30.0 to 200.0 mS/cm;
up to 500.0 mS/cm,
and absolute conductivity (TDS) is the conductivity value without temperature compensation
 Resolution   0.01 µS/cm;
0.1 µS/cm;
1 µS/cm;
0.01 mS/cm;
0.1 mS/cm
 Accuracy (@25°C)   ±1% of reading (±0.5 µS/cm or 1 digit, whichever is greater)
 Calibration   Cell factor calibration; six standards available: 84µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 118.8 mS/cm, one point offset: 0.00 µS/cm
   Temperature Compensation   Automatic, -5 to 100.0°C; NoTC, can be selected to measure absolute conductivity
 Temperature Coefficient   0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C
Logging   Up to 1000* (400) records organised in:
• Manual log-on demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging in Standard Mode, maximum 600 logs (100 lots)

TDS - using HI-763100 four-ring conductivity probe

   TDS Range   0.00 to 14.99 mg/L (ppm);
15.0 to 149.9 mg/L (ppm);
150 to 1499 mg/L (ppm);
1.50 to 14.99 g/L;
15.0 to 100.0 g/L;
up to 400.0 g/L absolute TDS using 0.80 conversion factor
 Resolution   0.01 mg/L (ppm);
0.1 mg/L (ppm);
1 (ppm);
0.01 g/L;
0.1 g/L
 Accuracy (@25°C)   ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
 Calibration   through EC calibration
 TDS Factor in Standard Mode   0.40 to 0.80 (default value is 0.50)

Salinity - using HI-763100 four-ring conductivity probe

   Salinity Range   0.0 to 400.0 % NaCl; 2.00 to 42.00 PSU; 0.00 to 80.00 g/L
 Resolution   0.1 % NaCl; 0.01 PSU; 0.01 g/L
 Accuracy (@25°C)   ±1% of reading
 Calibration % NaCl only   one point with HI-7037 standard

Dissolved Oxygen - using HI-764080 DO Probe

  DO Range   0.00 to 45.00 PPM (mg/L); 0.0 to 300.0% saturation
 Resolution   0.01 ppm (mg/L); 0.1% saturation
 Accuracy   ±1.5% of reading (± 1 digit)
 Calibration   one or two point at 0% (HI-7040L solution) and 100% (water-saturated air)
 Pressure Compensation   Automatic 450.0 to 850.0 mmHg – (0.1 mmHg resolution)
 Salinity Compensation   0 to 40 g/L – (1g/L resolution)
  Temperature Compensation   0.0 to 50.0°C)
   Logging   Up to 1000 records organised in:
• Manual log-on-demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging in Standard Mode, maximum 600 logs (100 lots)

Temperature

 Temperature Range   -20.0 to 120.0 °C
 Resolution   0.1°C
 Accuracy   ±0.5°C

Related Products