top of page
Conductivity Benchtop Meter with four-ring conductivity probe

Conductivity Benchtop Meter

£525.00 Regular Price
£498.75Sale Price

Hanna's conductivity benchtop meter enables fast, accurate measurements of conductivity, TDS, and temperature utilising Hanna digital probes – HI-763100 Digital Conductivity electrode (included) with temperature sensor. Ideal for laboratories, classrooms and general industry.

 

Available with and without data logging and PC connectivity. 

Quantity

EC - using HI-763100 four-ring conductivity probe

 EC Range   0.00 to 29.99 µS/cm;
30.0 to 299.9 µS/cm;
300 to 2999 µS/cm;
3.00 to 29.99 mS/cm;
30.0 to 200.0 mS/cm;
up to 500.0 mS/cm,
and absolute conductivity (TDS) is the conductivity value without temperature compensation
 Resolution   0.01 µS/cm;
0.1 µS/cm;
1 µS/cm;
0.01 mS/cm;
0.1 mS/cm
 Accuracy (@25°C)   ±1% of reading (±0.5 µS/cm or 1 digit, whichever is greater)
 Calibration   Cell factor calibration; six standards available: 84µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 118.8 mS/cm, one point offset: 0.00 µS/cm
   Temperature Compensation   Automatic, -5 to 100.0°C; NoTC, can be selected to measure absolute conductivity
 Temperature Coefficient   0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C

TDS - using HI-763100 four-ring conductivity probe

  TDS Range   0.00 to 14.99 mg/L (ppm);
15.0 to 149.9 mg/L (ppm);
150 to 1499 mg/L (ppm);
1.50 to 14.99 g/L;
15.0 to 100.0 g/L;
up to 400.0 g/L absolute TDS using 0.80 conversion factor
 Resolution   0.01 mg/L (ppm);
0.1 mg/L (ppm);
1 (ppm);
0.01 g/L;
0.1 g/L
 Accuracy (@25°C)   ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
 Calibration   through EC calibration
 TDS Factor in Standard Mode   0.40 to 0.80 (default value is 0.50)

Salinity - using HI-763100 four-ring conductivity probe

 Salinity Range   0.0 to 400.0 % NaCl;
2.00 to 42.00 PSU;
0.00 to 80.00 g/L
 Resolution   0.1 % NaCl;
0.01 PSU;
0.01 g/L
 Accuracy (@25°C)   ±1% of reading
 Calibration % NaCl only   one point with HI-7037 standard

Temperature

Temperature Range   -20.0 to 120.0 °C
 Resolution   0.1°C
 Accuracy   ±0.5°C

Additional Specifications

Logging   Up to 1000 (standard mode) (400) records organised in:
• Manual log-on demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging in Standard Mode, maximum 600 logs (100 lots)
PC Interface   USB-C
Storage Interface   USB-C
Power supply   USB Type C (5 VDC; 500mA)
Environment   0 to 50˚C; Maximum 95% RH non-condensing
Dimensions   205 x 160 x 77 mm
Weight   Approximately 0.85 kg

Related Products